Phi nanotof ii
Webb2、面扫+分析. 导出客户指定离子的 MAPPING, 所有离子统一用Thermal 颜色:右边的色标可以看出黑色是分布没有的区域,黄色白色是分布较多的区域; 3、深度剖析+数据分析. … WebbThe nanoTOF II is providing patented charge neutralization technique, which is directing very low energy electrons and argon ions to an insulating sample simultaneously. This …
Phi nanotof ii
Did you know?
Webb1 maj 2016 · Schematic of the PHI nanoTOF II with MS/MS. [177] In this instrument, the entire TOF-SIMS spectrum (except the precursor ions) is detected simultaneouslywith … WebbThe core technology of the VersaProbe II is PHI’s patented, monochromatic, micro-focused, scanning x-ray source which provides excellent large area and superior micro-area spectroscopy performance. Bruker Multimode 8 Atomic Force Microscope ›
Webb質量分析装置としては、PHI TRIF V nanoTOF(アルバック・ファイ株式会社)、PHI nanoTOF II(アルバック・ファイ株式会社)、TOF.SIMS5(株式会社日立ハイテクサ … Webb10 apr. 2024 · 提供了TOF-SIMS 5 iontof ,PHI NanoTOFII两种型号的飞行时间二次离子质谱仪,可做质谱、面扫、深度剖析这三类测试项目。. 同学们有测试需求时,需要注意以下几点送样要求:(1)深度剖析只能是块体样品,长宽1cm,厚度不超过5mm,不能太大,小一些没有问题;(2 ...
WebbPHI NanoTOF 3 PHI’s patented Parallel Imaging MS/MS mass spectrometer provides superior sensitivity, low spectral background, unique ability to image highly topographic … WebbThe authors have developed a parallel imaging MS/MS capability for the PHI nanoTOF II time-of-flightsecondary ion mass spectrometry (TOF-SIMS) instrument.
WebbPHI Quantes; PHI VersaProbe 4; PHI Quantera II™ PHI X-tool; Auger Electron Spectroscopy / AES, SAM. PHI 710; Time-of-Flight SIMS / TOF-SIMS. PHI nanoTOF 3; Dynamic-SIMS / D …
WebbThe PHI NanoTOF II mass spectrometer is equipped with a high-energy collision induced dissociation (CID) fragmentation cell as well as a second time-of-flight analyzer … shared printer and network printer differenceshared printer driver is unavailableWebbPHI NanoToF II ToF-SIMS Primary Ion Source: 30kV LMIG with Bi, Au, or Ga emitter Dual-beam Charge Neutralization Depth profiling enabled with 20kV C 60 Pulsed Ion Gun or 2 … shared printer driver update neededWebbThe PHI nanoTOF II TOF-SIMS instrument ensures that there are no compromises in analytical performance. It was designed with “The Power of And” in mind. This … pool together synonymWebbPhysical Electronics Inc. (PHI) forms as one of the first specialty companies for surface analysis instruments in the world, developed by Dr. R. E. Weber of the University of … pool to dining table conversionsWebb27 feb. 2024 · High lateral resolution 2D SIMS images were collected using a PHI nanoTOF II system in unbunched mode. Bi 3 ++ was employed as the primary ion with ∼ 0.5 pA Bi … shared printer cannot scan connect to laptopWebb19 maj 2024 · The PHI NanoTOF II mass spectrometer is equipped with a high-energy collision induced dissociation (CID) fragmentation cell as well as a second time-of-flight … shared printer ip address